Skip to main content
  • Blink

    Total Cupping

    By Roshni Ranjit, BS, BA, Dilip Rathinasamy, MD, and Timothy Saunders, MD, at University of South Florida Morsani College of Medicine, Tampa, and Peter Reed Pavan, MD, USF Eye Institute, Tampa, and edited by Michael P. Kelly, FOPS
    Photographed by Ken Albritton, USF Eye Institute, Tampa, Fla.

    Download PDF 

    Total Cupping

    A 63-year-old man presented for a cosmetic unilateral ptosis evaluation. His right lid had become symptomatic following a complicated history of retinal detachment procedures on that eye, including scleral buckle and lensectomy/vitrectomy with silicone oil injection. After the most recent surgery, visual acuity in the right eye was limited to light perception and later worsened to no light perception.

    On examination, intraocular pressure was 40 mmHg. A color fundus photo showed a deep and total cup with a retained silicone oil bubble.

    The eye was not painful, so no treatment was advised. The patient was referred to oculoplastics, where a lid repair was scheduled.

    BLINK SUBMISSIONS: Send us your ophthalmic image and its explanation in 150-250 words. E-mail to eyenet@aao.org, fax to 415-561-8575, or mail to EyeNet Magazine, 655 Beach Street, San Francisco, CA 94109. Please note that EyeNet reserves the right to edit Blink submissions.